4. Set the evaluation properties: CODE CONFIGURATION tab
¾ Set the following parameters:
- Codes: 2/5 Interleaved; deactivate all other code types! (remove check)
- Number of Codes: Minimum 1, Maximum 1
- Seperate codes dependent on reading angle: deactivate (remove check)
- Decoder: SMART/Standard
¾ For 2/5 interleaved, click on the E
DIT button.
The 2/5 I
NTERLEAVED tab then opens (Fig. 10-53).
¾ Set the following parameters:
- Code Length: Fixed; length 1: 14 characters
- Multiple Reads for Length 1: 3
- Check Digit Test for Length 1: mod 10
- Transmit Check Digit: activate
- Transmit Leading Zero: activate
¾ Close the tab.
Fig. 10-52: Parameterization example: settings on the "Code Configuration" tab
Fig. 10-53: Parameterization example: "2/5 Interleaved" tab