Operating Instructions Chapter 6
CLV490 Bar Code Scanner
8009993/RA61/2007-07-20 © SICK AG · Division Auto Ident · Germany · All rights reserved 6-49
Operation
Configuring and calling up I/O monitor for display
1. In the symbol bar, click or select CLV490, I/O MONITORING in the menu bar.
The S
IGNAL CHOICE dialog box is then displayed (Fig. 6-15).
2. Select the desired input, output or data transfer direction for each selection (entry) on
the left side in one of the drop-down lists.
3. Click the A
DD button.
The previously selected entry appears at the end of the list in the S
IGNALS TO PLOT field
to the right.
4. Repeat for other entries. A signal cannot be selected twice.
5. If necessary, delete undesired inputs, outputs or a data transfer direction from the list.
Select the relevant entry and click the R
EMOVE button. Several entries can be chosen
selectively by holding down the [CTRL] key and selecting with the left mouse button. A
block selection is done by holding down the [SHIFT] key and selecting with the left
mouse button.
6. If the sequence in the list is to be changed, select the desired entry and move it to the
preferred location using the "up arrow" and "down arrow" buttons. Several entries can
be moved selectively or as a block at the same time here as well.
7. After configuration is complete, click S
TART MONITORING.
CLV-Setup begins with the display of the switching statuses/data output in the I/O
M
ONITORING dialog box as soon as data is output from the CLV490. An example is shown
in Fig. 6-16.
8. To cancel the display, click C
LOSE in the I/O MONITORING dialog box and exit the SIGNAL
C
HOICE dialog box by clicking CLOSE.
– or –
Click E
XIT in the I/O MONITORING dialog box.
CLV-Setup resets the operating mode of the auxiliary interface to its original function.
This also applies when the S
IGNAL CHOICE dialog box is exited with CLOSE without having
started the I/O Monitor.
Fig. 6-15: CLV-Setup: Selection of the signals to be displayed in I/O Monitoring