SICK ICR890 Betriebsanleitung Seite 33

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 42
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 32
Online Help Chapter 2
ICR890
ICR890
8012178/0000/2008-01-28 © SICK AG · Division Auto Ident · Germany · All rights reserved 33
Example The following condition acts as an example (see. chapter 2.1.7.2 Evaluation Conditions,
page 28):
! Only barcodes of code type 128 that contain the character sequence "45" are to be out-
put.
! Condition is met:Output of "MATCHCODE" and the code content in the output string.
! Condition is not met:Output of "NOMATCH" in the output string.
! No valid code could be read:Output of "NoRead" in the output string.
To achieve this result, the following
CONDITION (see chapter 2.1.7.2 Evaluation Conditions,
page 28) and
OUTPUT FORMAT must be created.
2.1.8 Network / Interfaces / IOs
Network options Use the parameters of the Network options group to assign the device ID in the network.
Master / Slave The master/slave connection of the scanner in the SICK CAN sensor network is defined via
the parameters of the Master / Slave group.
Parameters Function
Device ID Enter CAN Bus address of the device.
Device name Enter device name.
This name is displayed at the top of the project tree.
The device name is used as the file name for the image output.
Parameters Function
Network function In a master/slave connection the device is always the slave.
assign to Select connection between the master and the slave.
Point of output Select output time of reading results.