SICK ICR890 Betriebsanleitung Seite 15

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 42
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 14
Online Help Chapter 2
ICR890
ICR890
8012178/0000/2008-01-28 © SICK AG · Division Auto Ident · Germany · All rights reserved 15
2.1.3 Increment
An external incremental encoder can be connected to determine the actual conveyor
speed.
The conveyor speed results from the number of impulses and the resolution of the external
incremental encoder. Alternatively, a fixed speed can be selected.
Increment The increment source and the resolution/speed are configured via the parameters of the
Increment group.
2.1.4 Image Output
Condition Use the parameters of the Condition group to define the conditions for the image output.
Parameters Function
Alpha Enter Alpha angle (see Fig. "Alpha angle").
Reading at right angle to conveyor 90°/270°
Beta Enter Beta angle (see Fig. "Beta angle").
Beta decile Enter decimal place for Beta angle for fine adjustment.
The fine adjustment is particularly important for exact configura-
tion of the side cameras.
Gamma Enter Gamma angle (see Fig. "Gamma angle").
Reading from the top: 0°
Reading from the side: 90°/270°
Parameters Function
Increment source Select increment source.
Fixed speed Enter speed of the conveyor distance.
If applicable, select unit.
System increment resolution Enter resolution of the external incremental encoder.
If applicable, select unit.
Parameters Function
Request Activate/Deactivate image output and select condition for the
image output.
Image format Select file format for the image output.
Bitmap scaling Select scaling factor for "bmp" file format.
100% = scale 1:1
50% = scale 1:2
25% = scale 1:4
JPEG quality Enter image quality for JPEG compression.
Activate diagnosis output Activate/Deactivate output of additional information together
with the image output.
Image diagnosis data is output as XML data.
Output limited by code position Activate/Deactivate whether the minimum and maximum code
position (see chapter 2.1.1 Reading Configuration, page 7) are to
be considered for the image output.