Operating Instructions Chapter 6
ICR890
Operation
8011325/0000/2006-10-24 © SICK AG · Division Auto Ident · Germany · All rights reserved 81
6.3.1 Overview of the configuration procedure
Connect data interfaces of the PC and the ICR890 System/MSC800
Start the SOPAS-ET Configuration Software and create a new project file
Configure the scan assistant (activate PC communication)
Establish communication with the ICR890 System/MSC800
Accept current configuration of the ICR890 System/MSC800 in the project tree
Use the password “client“ to register at the system as an “authorized client“
Configure the ICR890 System/MSC800 for use
Activate the image output of the SOPAS-ET Configuration Software (“Image Viewer“) to
check the reading
If necessary, apply the diagnosis tools “Reading Diagnosis“ and “Event Monitor“
(online presentation/recording of the switching statuses of switching inputs and
outputs as well as data transfers to the host)
Load the optimized configuration into the ICR890 System and save permanently
Save the project file with the configuration data of the ICR890 System/MSC800 at the
PC
6.3.2 Establishing communication with the ICR890 System/MSC800
Prerequisite The TCP-IP protocol at the PC has to be active to enable communication via TCP-IP.
Connecting data interfaces
¾ Interconnect the PC and the ICR890 System/MSC800 according to Tab. 6-2.
s
Connection via: At data interface: Comment
MSC800 ETHERNET 1
(10/100 MBps)
Connect the PC (Ethernet interface), MSC800 (ETHERNET 1
connection) and the ICR890 System (HOST ETHERNET connection) to
a joint switch using a patch cable no. 6030928 (10 m (32.8 ft)) or
no. 6029630 (3 m (9.84 ft)) for each connection.
MSC800 (optional) AUX 1 or HOST 1
(RS 232)
Connect the PC via a 3-wire null modem cable no. 2014054 to the
9-pole D-Sub connector AUX 1 of the MSC800.
ICR890 System HOST ETHERNET
(10/100 MBps)
Directly connect the PC (Ethernet interface) to the HOST ETHERNET
connection of the ICR890 System via a crossover cable.
- or -
Use the patch cable (1:1) no. 6030928 (3 m (9.84 ft)) or no.
6029630 (10 m (32.8 ft)) when connecting via a hub.
ICR890 System (optional) AUX or HOST
(RS 232)
Provide the cable no. 6028420 (open end) for connection to the PC
with a 9-pole D-Sub socket and, depending on the interface type,
configure it as a null modem cable.
(For wire colour assignment: see Tab. 5-31, page 75, transmitter and
receiver signals are crossed, see Fig. 5-6, page 66).
Connect the PC via the cable no. 6028420 to the AUX connection or
the ICR890 System HOST.
Tab. 6-2: Connection between the PC with the SOPAS-ET Configuration Software and the ICR890 System/MSC800